Campbell Sci – CMP11-L Solar Radiation

The CMP11 legacy pyranometer, manufactured by Kipp & Zonen, is an ISO secondary-standard pyranometer that monitors solar radiation for the full solar spectrum range. It connects directly to a Campbell Scientific data logger and is well-suited for meteorological networks and solar-energy research and development. In solar-energy meteorological stations, the CMP11 has been replaced by the CMP10.
DOWNLOAD DATASHEET

Description

Specifications

ISO Classification Class A (secondary standard)
Spectral Range 285 to 2800 nm
Sensitivity 7 to 14 µV/W/m2
Temperature Dependence of Sensitivity < 1% (-10° to +40°C)
Response Time < 5 s (95% of final value)
Zero Offset Due to Thermal Radiation < 7 W/m2 (200 W/m2)
Non-Stability < 0.5% (change/year)
Non-Linearity < 0.2% (0 to 1000 W/m2)
Directional Error < 10 W/m2 (up to 80° with 1000 W/m2 beam)
Tilt Error < 0.2%
Level Accuracy 0.1°
Impedance 10 to 100 Ω
Operating Temperature Range -40° to +80°C
Typical Signal Output 0 to 15 mV (for atmospheric applications)
Maximum Irradiance 4000 W/m2
Expected Daily Uncertainty < 2%
Dome Diameter 5 cm (2 in.)
Width 15 cm (5.9 in.) with shield
Height 9.25 cm (3.64 in.)
Weight 0.9 kg (2 lb) with 10.1 m (33 ft) cable

Additional information

Merek

Campbell Sci