Campbell Sci – CS100 Barometric Pressure

The CS100 is a Campbell Scientific version of Setra’s model 278 barometer. It uses Setra’s Setraceram capacitive sensor and IC analog circuit to measure barometric pressure.  The CS100 includes a 0.76 m (2.5 ft) cable and a terminal strip for data logger power and signal connections.

The CS100 is encased in a stainless-steel and polyester case fitted with an 1/8 in. barbed fitting for pressure connection. It includes an internal switching circuit that allows the data logger to power the barometer only during measurement, which reduces power usage.

DOWNLOAD DATASHEET

Description

Specifications

-NOTE- 1 hPa = 1 mBar
Pressure Range 600 to 1100 hPa
Long-Term Stability ±0.1 hPa per year
Response Time < 100 ms
Resolution ±0.01 hPa
Excitation 9.5 to 28 Vdc
Accuracy
  • Accuracy refers to the root sum squared (RSS) of end point non-linearity, hysteresis, repeatability, and calibration uncertainty.
  • ±0.5 hPa (@ +20°C)
  • ±1.0 hPa (@ 0° to 40°C)
  • ±1.5 hPa (@ -20° to +50°C)
  • ±2.0 hPa (@ -40° to +60°C)
Linearity ±0.4 hPa
Hysteresis ±0.05 hPa
Repeatability ±0.03 hPa
Signal Output 0 to 2.5 Vdc
Warm-up Time < 1 s
External Trigger Voltage
  • 0 Vdc (sleep mode)
  • 3 to 28 Vdc (operating mode)
Current Consumption
  • < 3 mA (active)
  • < 1 µΑ (sleep mode)
Operating Temperature Range -40° to +60°C
Cable Diameter 0.8 cm (0.3 in.)
Cable Length 0.8 m (2.5 ft)
Dimensions 9.1 x 6.1 x 2.5 cm (3.6 x 2.4 x 1.0 in.)
Weight 135 g (4.8 oz)

Additional information

Merek

Campbell Sci