Meter – ATMOS 22 Ultrasonic Anemometer

The ATMOS 22 was designed without moving parts, meaning there’s never any mechanical wear. No oiling or replacing bearings. And no recalibration required. Just reliability you can continue to count on.

Not only does its ultra-low power consumption make it ideal for long-term, remote installations, but its compact size makes it small enough to deploy inside canopies. And instead of having to make field visits to collect data and check sensor and system functions, you can monitor information in real time and download data using any internet-connected device by connecting the ATMOS 22 to a ZL6 data logger. Which not only saves you time, but provides worry-free operation and peace of mind.

DOWNLOAD DATASHEET

Description

SPECIFICATIONS

MEASUREMENT CHARACTERISTICS
Horizontal wind speed Range: 0–30 m/s
Resolution: 0.01 m/s
Accuracy: the greater of 0.3 m/s or 3% of measurement
Wind gust Range: 0–30 m/s
Resolution: 0.01 m/s
Accuracy: the greater of 0.3 m/s or 3% of measurement
Wind direction Range: 0°–359°
Resolution: 1°
Accuracy: ±5°
Tilt Range: -90° to 90°
Resolution: 0.1°
Accuracy: ±1°
COMMUNICATION SPECIFICATIONS
Output SDI-12 communication
Data logger compatibility (not exclusive) METER ZL6, Em50, and EM60 data loggers or any data acquisition systems capable of 3.6- to 15.0-VDC excitation and SDI-12 communication
PHYSICAL CHARACTERISTICS
Dimensions Diameter 10 cm (3.94 in)
Height 16 cm (6.30 in)
Operating temperature range Minimum: –50 °C
Maximum: 60 °C
Cable length 5 m (standard)
75 m (maximum custom cable length)NOTE: Contact Customer Support if a nonstandard cable length is needed.
Connector types 3.5-mm stereo plug connector or stripped and tinned wires
ELECTRICAL AND TIMING CHARACTERISTICS
Supply voltage (VCC to GND) Minimum 3.6 VDC continuous
Maximum 15.0 VDC continuousNOTE: The ATMOS 22 must be continuously powered to work properly.
NOTE: For the ATMOS 22 to meet digital logic levels specified by SDI-12, it must be excited at 3.9 VDC or greater.
Digital input voltage (logic high) Minimum 2.8 V
Typical 3.0 V
Maximum 5.5 V
Digital input voltage (logic low) Minimum –0.3 V
Typical 0.0 V
Maximum 0.8 V
Digital output voltage (logic high) Typical 3.6 V

NOTE: For the ATMOS 22 to meet digital logic levels specified by SDI-12, it must be excited at 3.9 VDC or greater.

Power line slew rate Minimum 1.0 V/ms
Current drain (during measurement) Minimum 0.050 mA
Typical 0.125 mA
Maximum 0.500 mA
Current drain (while asleep) Minimum 0.050 mA
Typical 0.125 mA
Maximum 0.150 mA
Power up time (SDI Ready)—aRx! commands Typical 10 s
Power up time (SDI Ready)—other commands Typical 800 ms
Measurement duration Typical 110 ms
Maximum 3,000 ms
Compliance Manufactured under ISO 9001:2015
EM ISO/IEC 17050:2010 (CE Mark)