WaterLOG – XL Series Data Logger

If you’re looking for a data logger with a fully integrated HDR transmitter the H-522 and H-522+ are your models. Capable of communicating through GOES or INSAT satellites, these models are designed for use in remote monitoring applications.  The H-522 and H-522+ allow your to transmit data storage and sensor values to a satellite network for near real-time data retrieval. If you don’t have the need for a display, the H-522 is your model, but keep in mind, the H-522+ is our top seller, with close to 6000 units in operation to date.

If built in satellite transmission is overkill, you might appreciate the more cost-conscious 350XL or 500XL models.  Refer to the specifications tab to see all the available options for our dataloggers.

DOWNLOAD DATASHEET

Category: Tags: , , ,

Description

Graphic Display Yes
Operating Temperature -40 ° to +60 ° C
Power Power Requirements: Voltage Input 11.0 to 16.0V; Current: Stabdby 12 mA Max, Active Transmitting <2.75 A
Storage Temperature -40 ° to +80 ° C
Warranty 2 years
Quick Specs
H-500XL H-350XL H-522 H-522+
Keyboard Display Yes Yes Yes
Pressure Sensor Optional1 Built-in Optional1 Optional1
GOES/INSAT Satellite transmitter Optional2 Optional2 Built-in Built-in

1 Can interface to the H-3531 external pressure sensor.
2 Can interface to an external H-2221 Satellite transmitter for GOES or METEOSAT; or to an external H-222 DASE (signal engineering) transmitter for INSAT.

Specifications indicate typical performance and are subject to change.

Pressure Transducer  (H-350XL only)
Accuracy Less than or equal to 0.02% of full scale output (FSO) over temperature range
Range 0 to 15 psi (0 to 34 ft (11m)); Accuracy = ±0.007 ft (2.1 mm)

0 to 30 psi (0 to 69 ft (21 m)); Accuracy = ±0.014 ft (4.3 mm)

Custom calibration ranges available to 100 psi

Media Compatibility Non-corrosive dry gases only
Analog Inputs
Channels 4 single ended, 1 differential
Resolution 24-bit resolution
Accuracy ±0.02% FS
Range o to 5 V (all channels); 0 to 500 mV (additional on channel 1)
+5.0 Volt Excitation
Accuracy ±5.0 mV over load and temperature range
Current 10 mA max load
Switched +12.0 Volt Excitation
Type Unregulated based on battery voltage
Current 2.5 Amps
Frequency Input
Range 1 to 10 KHz at ±75 mV PP or greater; 1 to 15 KHz at 1 V PP or greater
Amplitude ±5.0 V max
Accuracy ±0.1%x
Counter Inputs
Type Switch closure or voltage pulse
Voltage Input 0-5 V
Frequency Input 100Hx max
Digital I/O
Channels 2, independently configured for input or output
Input Levels 0.0 to 5.0 volts; (High ≥ 3.5 V, Low ≤ 0.8 V)
Output Levels High = 3.5 V Min Sourcing 5 mA; Low = 0.4 V Max Sinking 5 mA
4-20mA Output
Accuracy ± 0.5% FSO
SDI-12
Type Supports both Master and Slave modes
Connector 3-pin connector
RS-232
Type 3 RS-232 communication ports
Connector 9-pin D connector, female
Baud Rate Programmable
Memory
Data Storage Capacity 256 MB, Non-Volatile FLASH
Communications
 Type
USB 1 Host USB-A Connector, 1 Device Mini-B Connector; Version 2.0
External Satellite (H-350/H-500) GOES/INSAT H-2221-V2
Keypad Display 1 line 20 character vacuum florescent LED display
Environmental
Operating Temperature -40 ° to +60 ° C
Storage Temperature -40 ° to +80 ° C
Humidity
100% non-condensing
Power
H-350 / H-500 H-522+
Voltage Input 10.0 to 16.0 V 11.0 to 16.0 V
Current Standby: 5 mA Max; Active: see manual Standby: 12 mA Max; Active Transmitting: <2.75 A
Physical
H-350 / H-500 H-522+
Housing Size
(LxWxH)
7 in. x 8.5 in. x 4.3 in.

(180 mm x 220 mm x 110 mm)

9.5 in. x 11 in. x 6 in.

(241.3 mm x 279.4 mm x 152.4 mm)

Shipping Weight 4.25 lbs (2 kg) 7.5 lbs (3.4 kg)
Material Fiberglass with clear Lexan® window. Fiberglass (does not have clear Lexan® window)

Additional information

Merek

WaterLOG