Campbell Sci – CMP6-L Solar Radiation

The CMP6 measures solar radiation with a high-quality blackened thermopile protected by two glass domes. Its flat spectral sensitivity, from 285 to 2800 nm, makes it ideal for applications in natural sunlight, under plant canopies, in green houses or buildings, and inverted to measure reflected solar radiation.

A desiccant-filled drying cartridge prevents dew from forming on the inner sides of the CMP6’s domes. Campbell Scientific also offers the CVF4 heater/ventilator that keeps its domes free from ice and dew.

 
DOWNLOAD DATASHEET

Description

Specifications

ISO Classification Class B (first class)
Spectral Range 285 to 2800 nm
Sensitivity 5 to 20 μV W-1 m2
Temperature Dependence of Sensitivity < 4% (-10° to +40°C)
Response Time < 18 s (95% of final value)
Zero Offset Due to Thermal Radiation < 15 W/m2 (200 W/m2)
Non-Stability < 1% (change/year)
Non-Linearity < 1% (0 to 1000 W/m2)
Directional Error < 20 W/m2 (up to 80° with 1000 W/m2 beam)
Tilt Error < 1%
Level Accuracy 0.1°
Impedance 20 to 200 Ω
Operating Temperature Range -40° to +80°C
Typical Signal Output 0 to 20 mV (for atmospheric applications)
Maximum Irradiance 2000 W/m2
Expected Daily Uncertainty < 5%
Dome Diameter 5 cm (2 in.)
Width 15 cm (5.9 in.) with shield
Height 9.25 cm (3.64 in.)
Weight 0.9 kg (2 lb) with 10.1 m (33 ft) cable

Additional information

Merek

Campbell Sci